| Rated voltage |
250 Vac |
| Rated frequency |
50/60 Hz |
| Climatic category |
CM-2 CMI-2 = 25/85/21 CMS-2 CMS-4 = 25/100/21 |
| Working temperature |
CM-2 CMI-2 = -25°C +85°C CMS-2 CMS-4 = -40°C +100°C |
| Test voltage |
Between terminals: 500 Vac x 2" Between terminals and case: 2000 Vac x 2" |
| Dissipation factor |
tang <= 20 x 10-4 (Vn 50 Hz) |
| Approvals |
IMQ - ENEC |
| Reference standards |
EN61048 - EN61049 AMDT 1 e AMDT 2 |
| Terminals CM2 - CMI2 |
Unipolar rigid leads insulated |
| Terminals CMS2 - CMS4 |
Plug-in adaptor - faston 2.8 mm |
| Capacitance tolerance |
+/- 10% |
| Discharge resistor |
Included for CM-2 e CMI-2 In plug-in for CMS-2 e CMS-4 |
| Condensation |
Non permitted |
| Safety device |
CMi-2 thermal fuse CMS-2 CMS-4 = over pressure break-action |
| Degree of protection |
IP 00 |